RF Microneedling Device
UNTLaser RF microneedling device is a professional medical aesthetics device that combines microneedling and radiofrequency technology. It can directly apply RF heat energy to the dermis and is suitable for a variety of anti-aging and skin management projects. While deeply activating collagen repair, it also considers operational comfort and shortens postoperative recovery time.
Besides standard equipment supplies, we specialize in OEM and ODM customization that truly meet market needs and treatment logic. Our RF microneedling device supports customization of multiple contents such as equipment appearance, brand logo, operating interface, language system, needle specifications, and packaging solutions. Instrument parameters and applicable items can also be adjusted to fit different project directions, such as anti-aging, acne pit repair, and body tightening.
We help you create featured products faster, build differentiated competitive advantages, and enhance your brand competitiveness and project operational value. Feel free to contact us for your exclusive solution.

- 0.1mm Ultra-Fine Microneedles
- 415nm Blue Light Therapy
- Negative Pressure Suction
- Tri-Frequency RF (1/4/8MHz)
- Smart Guidance System

- 0.1mm Ultra-Fine Microneedles
- 415nm Blue Light Therapy
- Negative Pressure Suction
- Tri-Frequency RF (1/4/8MHz)
- Smart Guidance System

- 0.1mm Ultra-Fine Microneedles
- 415nm Blue Light Therapy
- Negative Pressure Suction
- Tri-Frequency RF (1/4/8MHz)
- 4-in-1 Treatment Platform
Adjustable Depth for Stable Clinical Performance
UNTLaser RF microneedling device uses insulating microneedling technology, which allows RF energy to reach the dermis directly, reducing thermal stimulation to the epidermis and achieving precise and controllable collagen regeneration and repair. The needle depth can be freely adjusted in the range of 0.5–4.0mm. Combined with the real-time RF energy regulation function, treatment can be flexibly adjusted according to different skin problems and locations, and energy output can be kept stable and uniform. By combining these technologies, you can achieve better treatment results, greatly reduce operational risks, and receive higher customer trust.


Smart RF Microneedling for Comfortable Treatments
The UNTLaser RF microneedling device has an intelligent cartridge recognition system. It auto-detects 10-pin, 49-pin, and other cartridges and matches proper treatment parameters, reducing manual errors and ensuring consistent results. Its 0.1mm ultra-fine needles minimize skin damage and pain. Safe for sensitive areas, it brings a pleasant experience for clients. You can attach an extra hot & cold hammer handpiece to soothe skin with a cold compress after treatment. It eases post-procedure discomfort for better recovery. These features can reduce the high demands on operator experience and make the daily operation management of your project more standardized and reliable.
Multi-Treatment Platform for Flexible Practice Management
The UNTLaser microneedling RF machine is available in a variety of needle sizes and replaceable microneedling needles that can be freely replaced on demand. It can be flexibly switched according to the treatment site and project needs, and can be applied to the face, eye area, neck, and body parts. The combination of various needles takes into account both therapeutic effects and operating efficiency. The device can more flexibly carry out a variety of popular projects, such as skin tightening and rejuvenation, acne pit repair, pore contraction, and anti-aging. Help you enrich the service categories in the store, attract more customers, improve equipment usage, and be more conducive to the operation of long-term comprehensive treatment projects.

RF Microneedling Device Specification
| Category | Parameter | Description |
| RF Energy System
| RF Output Mode | Bipolar |
| RF Frequency | 1MHz / 4MHz / 8 MHz (optional configurations) | |
| Energy Adjustment | Multi-level adjustable/real-time control system | |
| Output Control | Real-time energy feedback for improved stability | |
| Microneedle System
| Needle Depth | 0.5 – 4.0mm |
| Needle Cartridges | 10 pin / 36 pin / 64 pin | |
| Needle Type | Insulated / Non-Insulated | |
| Insertion Method | Vertical microneedle structure | |
| Device Performance
| Drive System | High-speed digital motor control |
| Treatment Speed | Continuous high-efficiency output design | |
| Stability | Uniform energy delivery control | |
| Clinical Experience
| Cooling System | Integrated skin cooling technology |
| Treatment Modes | Pre-set modes (Anti-aging / Acne / Pores / Tightening) | |
| User Interface | Smart touchscreen UI system | |
| Safety System
| Protection Mechanism | Overheat protection/energy limitation system |
| Safety Control | Real-time output monitoring | |
| Business Configuration
| Customization | OEM / ODM support |
| Appearance Customization | Logo/device housing customization | |
| Consumables System | Replaceable needle cartridge system |
Functions of Our RF Microneedling Device

Radiofrequency microneedles act on the dermis to stimulate collagen regeneration, improve skin firmness while controlling epidermal thermal stimulation, making the anti-aging effect more stable, and improve customer satisfaction and repeat rate to repurchase.

For acne pits and pore problems, microneedling and radiofrequency work together to improve skin structure, gradually smoothing and refining skin texture, and enhancing the stability and visible effects of your repair projects.

Act on body areas such as the waist, abdomen, and thighs to promote deep collagen regeneration, improve sagging and line problems, make body firming projects more effective and supportive, and enhance the overall commercial value of your projects.
A practical guide to RF Microneedling Device
Use this image-free guide to review the information and frequently asked questions already published for this machine category.
How to Choose the Right RF Microneedling Device
Safety & Stability
The first and most important thing is whether the RF microneedling machine can be used safely for long-term stable and safe operation performance. Because RF microneedles are energy devices, if the output is unstable or the thermal control is insufficient, it may cause problems such as epidermal burning and pigmentation, which will further lead to customer complaints or customer complaint risks.
So you need to see whether the RF output is stable and consistent, whether the RF energy output is uniform and stable, whether the RF microneedling device has an overheating protection and energy limiting mechanism, and whether the needle insertion depth is accurately controllable. A stable system should ensure that energy is always within a safe thermal action range and maintain the predictability of tissue responses during treatment.
| Parameter | Industry Range |
| Needle Depth | 0.5 – 4.0 mm (facial use) |
| Extended Depth | Up to 4 mm (body treatment) |
| RF Frequency | 1 MHz / 4 MHz / 8 MHz |
| Safe Tissue Temperature | 55℃-65℃ |
| Depth Adjustment Precision | 0.25 mm step |
Clinical Effectiveness
After confirming that the device is safe and easy to use, the next step is to focus on the actual use effect. The key to the core effect of the RF Microneedling machine lies in whether radiofrequency energy can stably act on the dermis, relying on different needle insertion depths to achieve layered thermal stimulation, activate collagen regeneration, and reshape skin structure. At the same time, whether the improvement effect of the RF microneedling machine on various skin types is balanced and unified is also the focus of judging the value.
| Parameter | Industry Range |
| Thermal Effect Temperature | 55°C – 65°C |
| Collagen Activation Start | 2 – 4 weeks |
| Full Remodeling Cycle | 3 – 6 months |
| Treatment Sessions | 3 – 6 sessions |
| Acne Scar Improvement Rate | 30% – 50% (clinical range) |
Treatment Range
The scope of application of radio frequency microneedle instruments determines their practical value. The skin problems that can be improved by the microneedling RF machine are achieved through the depth adjustment of the needle, multi-gauge needles, and the rational combination of microneedle structures.
You need to flexibly adjust various parameters to complete layered care from surface skin care to deep dermal repair, so that the equipment can be adapted to various medical beauty care projects, such as face and body.
| Parameter | Industry Range |
| Facial Treatment Depth | 0.5 – 4.0mm |
| Body Treatment Depth | 3 – 4+ mm |
| Needle Cartridge Types | 10-pin/ 36-pin/ 64-pin |
| Treatment Applications | Acne scars/pores / tightening / body contouring |
| Treatment Layers | Epidermis / Dermis / Superficial subcutaneous tissue |
Operational Efficiency
This is not a hard requirement, but it can greatly improve the efficiency of your project. In actual store operations, whether the equipment is good to use and the operating effect is stable or unstable directly determines whether it can be promoted and used in batches. Excellent RF Microneedling equipment should have reduced requirements for operator experience. The built-in preset mode or standardized process reduces learning costs, and different personnel can also achieve uniform and stable results.
| Parameter | Industry Range |
| Treatment Duration | 20 – 60 minutes |
| Needle Configurations | 10 – 64 pin |
| Coverage Efficiency | 10-pin (precision) / 36-pin (large area) |
| Training Period | 1 – 3 weeks (standard systems) |
Frequently Asked Questions
What Is the Difference between the RF Microneedling Device and Traditional Microneedling?
Traditional microneedles only rely on subtle wounds to stimulate skin self-repair. Most of them can only improve superficial acne scars, rough skin texture, and light lines. The scope of action basically stays in the surface layer of skin and superficial dermis.
RF Microneedling device superimposes radiofrequency thermal energy on microneedles, which can penetrate deep into the dermis for warm stimulation and better produce collagen. In contrast, it focuses more on deep lifting and firming, toning the skin from the root, and not just making surface improvements.
Are RF Microneedling Device Consumables Expensive?
The main consumable of RF microneedle equipment is disposable needle cartridges. The cost of cartridges of different specifications is slightly different, but this expense is a routine expenditure in the daily operation of the store. All needle cartridges are disposable and should never be reused. It can not only ensure operation hygiene and customer safety, but also effectively avoid cross-contamination and reduce the risk of infection.
Compared with simply looking at the unit price of consumables, the adaptability and stability of consumables are actually more important for the long-term operation of stores. Our device comes with multiple needle sizes and a unified interface to meet different treatment needs. Multiple uses of one machine not only increase equipment usage but also help stores improve efficiency and increase revenue.









