UNTLaser XFocus3 CO2 Fractional Skin Resurfacing Machine
- 10,600nm Precision Laser
- Adjustable Spot Size & Patterns
- Tailored Precision, Faster Healing
Key Benefits of XFocus3 CO2 Fractional Skin Resurfacing Machine
XFocus3 is a multifunctional CO₂ fractional laser medical beauty platform. It uses matrix scanning with a 10.6 μm laser to create controlled microthermal injury zones on the skin or mucous membranes, rapidly vaporizing target tissue and activating collagen regeneration and tissue remodeling. The device integrates four core treatment modes: fractional skin rejuvenation, ultra-pulse minimally invasive ablation, gynecological intimate area restoration, and vulvar pigmentation management.
- 40W Coherent RF laser, 400mJ max single pulse energy.
- 7-joint arm, 4 handpieces with integrated smoke extraction.
- Gynecology 45° & 360° fittings, vulvar oblique, with vaginal support frames.
- 10.4-inch touchscreen, 4 modes, 5 storable protocols, scan up to 20×20mm.
- Class 4 safety, dual interlock, emergency stop, fault code alerts.
- 110–240V global voltage, air/water cooling, key-switch power control.
One Laser, Total Skin Renewal & Feminine Rejuvenation

Fading Acne Scars, Pores & Dark Spots

A Tighter Vagina & Less Urine Leaking

Brighter, Pinker Vulva & Areola Tone
Proven USA Coherent 40W Core
The device is equipped with a U.S.-made Coherent metal RF laser tube, whose 40W peak power is 33% higher than that of traditional 30W glass tubes. Energy remains consistent even during continuous daily operation. Single-pulse energy is adjustable from 1 to 400 mJ in 1 mJ increments, offering precise settings for everything from superficial pigmentation to deep pitted scars and stretch marks. The machine is rugged and durable, with a low failure rate and high treatment consistency, reducing customer complaints.

4 Handpieces, One Platform
Four specialized handpieces are provided as standard equipment: fractional scanning, ultra-pulse cutting, gynecological intimate area treatment, and vulvar treatment. The fractional scanning handpiece also offers three funnel-shaped attachments for different ablation depths. A single device covers full-face skin rejuvenation, acne scar repair, intimate area tightening, vulvar lightening, and excision of skin growths. You don’t need to purchase multiple machines; simply swap handpieces to expand your service offerings, saving both space and budget.
Smart Touch Panel & Safety Layers
A 10.4-inch full-color touchscreen with Chinese and English languages, one-touch switching between four modes, and one-touch access to five sets of commonly used parameters. Safety is a top priority, offering a dual Standby/Ready lock, an emergency stop button, a key switch, and self-test alarms for water flow, temperature, and galvanometer, all part of a robust Class 4 laser safety system. Technicians can get up to speed quickly, training costs are low, and the entire treatment process is compliant- one less thing to worry about and one more layer of business protection.
Visible Facial Rejuvenation Results
Before
After
Before
After- Specification
- Manufacturing & Quality
- 24/7 Support
Specification
| Parameter | Details |
| Screen | 10.4-inch LCD real color touch screen |
| Light Conducting System | 7 jointed arms to conduct light |
| Available Treatment Head | Scan, UltraPulse, Gynecology, Andrology |
| Wavelength | 10.6μm |
| Power | 40W |
| Mode | Scan, Normal |
| Laser Energy | 1–400mJ |
| Step Value | 1mJ |
| Scan Pattern Size | 0.1 × 0.1mm–20 × 20mm |
| Dot Quantity | 40,000 dots at most |
| Pulse Duration | 0.2–4ms (Fractional); 0.1–10ms (Normal) |
| Spot Distance | 0.1–2mm |
| Pulse Energy | 1mJ to 400mJ |
| Cooling System | Air cooling system |
| Laser Apparatus | Sealed-off laser device stimulated by direct current |
| Condenser Focus | f=100mm |
| Spot Size | 2.0 ± 0.2mm |
| Radiation Time | 0.011s |
| Main Machine Size | 45 × 33 × 113cm |
Manufacturing & Quality
Since 2010, Beijing UNT has specialized in the manufacturing of medical aesthetic lasers. Holding key certifications such as CE, FDA, MDR, and MDSAP, we clear your market access path by ensuring compliance. Our 10,000-square-meter factory implements end-to-end quality control, covering everything from incoming material inspection, assembly and wiring, to pre-testing and final testing.
Our R&D team includes engineers specializing in electronic engineering, AVR programming, structural design, UI, and quality control, supporting in-depth OEM/ODM customization of the device’s exterior, hardware circuitry, and system software. Each unit receives power calibration and burn-in testing before shipment, and with ample spare parts inventory, we ensure rapid order response. Backed by 14 years of laser technology expertise, we provide you with worry-free distribution and stable repeat purchases from end-users. Our global distributor network spans Asia, Europe, the Americas, Africa, and Oceania, offering 24-hour after-sales technical support.
24/7 Support
On-Site Clinical Training, Not Just a Manual
Engineers provide hands-on, step-by-step instruction on the day of installation, covering the entire process from fractional and pulsed cutting to intimate treatment modes. A standard clinical parameter reference chart is provided, helping technicians get up to speed quickly so they can begin treating patients right after training.
24-Hour Remote Tech Support, Zero Downtime
If the device triggers an alarm or displays an error, contact after-sales support directly; simply provide the device serial number and error code for remote diagnosis. No need to wait for an engineer to visit; common issues are identified and resolved within minutes, so your business never has to stop.
Original Spare Parts & Warranty Protection
We maintain a stock of core spare parts and never cut corners by using third-party substitutes. During the warranty period, repairs for non-human-caused malfunctions are free of charge. Unauthorized disassembly will void the warranty; genuine parts and authorized service are essential for ensuring the long-term reliability of your equipment.
FAQ
Traditional CO₂ lasers act like a bulldozer, grinding away the entire layer of the epidermis, removing both healthy and damaged skin. This leaves a large, moist wound that heals slowly and carries a high risk of infection. The CO₂ fractional laser breaks the beam into an array of micro-beams as thin as a strand of hair, removing only tiny spots at a time. The normal skin between the spots acts as “repairers”; scabs form and fall off within three to five days, redness and swelling subside quickly, and the likelihood of hyperpigmentation is sharply reduced.